BMZGH - HARMONY AW 46

  • MSDS: BMZGH
  • Manufacturer: PETRO CANADA INC
  • Product Name: HARMONY AW 46
  • National Stock Number: 9150-00-966-8833
Product Identification

Product ID:HARMONY AW 46
MSDS Date:02/15/1991
FSC:9150
NIIN:00-966-8833
MSDS Number: BMZGH

Responsible Party
PETRO CANADA INC
PETRO CANADA CENTER
CALGARY, ALBERTA

Emergency Phone: 403-296-3000

Info Phone: 403-296-3000

Cage: MO401

Contractor
PETRO-CANADA/CANADIAN COMMERCIAL CORP
2844 CALGARY, AB CA

Telephone: 403-296-3000

Cage: 14051

Ingredients

HIGHLY REFINED BASE OIL

CAS: 72623-87-1

Fraction By Weight: >98%


ORGANO-ZINC ADDITIVES

Fraction By Weight: <1%


POUR POINT DEPRESSANT

Fraction By Weight: <1%

Hazards

LD50 LC50 Mixture:LD50 (ORAL RAT) IS > 5000 MG/KG
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION-IF SPRAYED OR MISTED MAY
CAUSE CHEMICAL PNEUMONOTIS. SKIN/EYE-MILDLY IRRITATING. PROLONGED
OR REPEATED CONTACT WITH SKIN MAY CAUSE MILD IRRITATION & POSSIBLY
DERMATITIS. INGESTION-LOW TOXIC ITY ON INGESTION.
Explanation of Carcinogenicity:THIS COMPOUND CONTAINS NO INGREDIENTS AT
CONCENTRATIONS OF 0.1% OR GREATER THAT ARE CARCINOGENS OR SUSPECT
CARCINOGENS.
Effects of Overexposure:INGESTION-HAS LAXATIVE EFFECT.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:SKIN-REMOVE CONTAMINATED CLOTHING. LAUNDER BEFORE REUSE. SOAP
& WATER WASH. EYES-COPIOUS WARM WATER FLUSH 15 MINUTES. PHYSICIAN
ASSESSMENT IF EYE INFLAMED. INHALATION- EVACUATE TO FRESH AIR.
APPLY C PR IF REQUIRED. ADMINISTER OXYGEN IF AVALIABLE. IF
RESUSCITATION IS REQUIRED, CONTACT PHYSICIAN. INGESTION-DO NOT
INDUCE VOMITING. FORCE FLUIDS. ACTIVATED CHARCOAL TABLETS.

Fire Fighting

Flash Point Method:COC
Flash Point:370F,188C
Autoignition Temp:Autoignition Temp Text:>250C
Extinguishing Media:DRY CHEMICAL OR CARBON DIOXIDE FOR SMALL FIRES.
WATER SPRAY OR FOAM FOR LARGE FIRES.
Fire Fighting Procedures:CONTAIN SPILL. COVER WITH EXTINGUISHING AGENT.
USE WATER SPRAY TO COOL FIRE EXPOSED CONTAINERS. DO NOT POINT SOLID
WATER STREAM DIRECTLY INTO BURNING OIL.
Unusual Fire/Explosion Hazard:ADDITION OF WATER OR FOAM MAY CAUSE
FROTHING. DO NOT CUT, DRILL OR WELD EMPTY CONTAINERSS.

Accidental Release

Spill Release Procedures:CONTAIN SPILL. ABSORB WITH INERT ABSORBENT
SUCH AS DRY CLAY, SAND OR DIATOMATIOUS EARTH, COMMERCIAL
ABSORBENTS, OR RECOVER USING PUMPS. SCOOP UP USED ABSORBENT AND
RAGS INTO DRUMS.

Handling

Handling and Storage Precautions:STORE IN COOL, WELL VENTILATED AREA.
Other Precautions:AVOID INHALATION AND SKIN CONTACT.

Exposure Controls

Respiratory Protection:NORMALLY NOT NECESSARY. IF MIST GENERATED BY
HEATING, SPRAYING, ETC. WEAR APPROVED ORGANIC VAPOR RESPIRATOR
SUITABLE FOR OIL MIST IN AREAS WITH SUFFICIENT OXYGEN.
Ventilation:GENERAL VENTILATION.
Protective Gloves:VITON, NITRILE OR PVC GLOVES
Eye Protection:CHEMICAL SPLASH GOGGLES
Other Protective Equipment:WEAR LONG SLEEVED CLOTHING TO MINIMIZE SKIN
CONTACT.
Work Hygienic Practices:WASH HANDS AFTER HANDLING AND BEFORE EATING.
LAUNDER WORK CLOTHING FREQUENTLY. DISCARD SATURATED LEATHER GOODS.
Supplemental Safety and Health
NOTE TO PHYSICIAN; GASTRIC LAVAGE SHOULD ONLY BE DONE AFTER
ENDOTRACHEAL INTUBATION IN VIEW OF THE RISK OF ASPIRATION WHICH CAN
CAUSE SERIOUS CHEMICAL PNEUMONITIS FOR WHICH ANTIBIONTIC AND
CORTCOSTERO ID THERAPY MAY BE INDICATED.

Chemical Properties

HCC:V6
Boiling Pt:B.P. Text:349C-550C
Vapor Pres:<0.001 KPA
Spec Gravity:0.86-0.87
Viscosity:21 CST
Solubility in Water:NEGLIGIBLE
Appearance and Odor:PALE, STRAW-YELLOW VISCOUS LIQUID WITH HYDROCARBON
ODOR.
Percent Volatiles by Volume:0%

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS (PEROXIDES, CHLORINES, STRONG ACIDS, ETC.).
Stability Condition to Avoid:EXCESSIVE HEAT, FORMATION OF OIL MIST.
Hazardous Decomposition Products:OXIDES OF CARBON, OXIDES OF SULFUR,
SMOKE ON COMBUSTION.

Disposal

Waste Disposal Methods:DISPOSE IN APPROVED, SECURE LANDFILL SITE OR
LICENSED WASTE RECLAMIMER FACILITY.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.